Welcome to Our Company
Call Us
Call Us
+8613267004347
DH-300A-3 Heat Deformation Temperature Vicat Softening Point Apparatus

DH-300A-3 Heat Deformation Temperature Vicat Softening Point Apparatus

2142.0 USD ($)/Set

Product Details:

  • Power Supply Manual
  • Hardness Yes
  • Material MS
  • Features Good Quality
  • Usage Hospital
  • Voltage 110-215 Volt (v)
  • Color White
  • Click to view more
X

DH-300A-3 Heat Deformation Temperature Vicat Softening Point Apparatus Price And Quantity

  • 2142.0 USD ($)/Set
  • 1 Set

DH-300A-3 Heat Deformation Temperature Vicat Softening Point Apparatus Product Specifications

  • 110-215 Volt (v)
  • White
  • MS
  • Good Quality
  • Hospital
  • Manual
  • Yes

DH-300A-3 Heat Deformation Temperature Vicat Softening Point Apparatus Trade Information

  • Shenzhen
  • Paypal, Telegraphic Transfer (T/T), Western Union
  • 300 Set Per Month
  • 7 Days
  • standard exporting package
  • All India

Product Description

DH-300A-3Heat Deformation Temperature Vicat Softening Point Apparatus


Application:


This machine is a non-metallic material testing instrument designed and manufactured according to the latest international standards and national standards. It is mainly used for non-metal such as plastic, hard rubber, nylon, electrical insulating materials, long fiber reinforced composite materials, high strength thermosetting laminates. Determination of the heat distortion temperature of the material and the Vicat softening point temperature. It is easy to operate and precise in control. It is a highly intelligent test instrument widely used in colleges and universities, research institutes and product quality supervision and inspection units. It adopts single-chip control, PID phase-modulated output, with upper limit temperature setting, and automatically stops heating when the test temperature reaches the upper limit temperature.



Standards:


GB/T1633 "Determination of vicat softening temperature (VST) of thermoplastics"

GB/T1634 "Determination of plastic load deflection temperature part 1: general test method"

GB/T8802 "Determination of softening temperature of plastic pipe fittings"

IS075-2013 "Determination of plastic load deformation temperature"

ASTM D 648 "Plastic heat deflection temperature test method"

ASTM D 1525 "Plastic vicat softening temperature test method"


Advantages:


1.Intelligent PID adjustment, accurate heating rate, precise temperature control

2.Can do thermal deformation test of various standard specimen

3.Can do Vicat softening point test of various standard specimen

4.The required load can be automatically calculated according to the test standard and sample size

5.Two heating rates can be selected, free switching, simple operation

6.When the test is completed or the temperature exceeds the upper limit, the temperature control will be turned off and shut down automatically

7.With software over-temperature protection and leakage protection



Specification:


  • Temperature control range: ambient temperature-300 degree
  • Deformation measurement range: 0-10mm
  • Number of sample racks: 3
  • The weight of the load bar and the tray: 76g
  • Test span range: 64 or 100mm according to the standard
  • Fuel tank volume: about 13L
  • Heating medium: methyl silicone oil
  • Cooling method: built-in active air cooling or external water cooling
  • Heating power: 2kw
  • Appearance size: length 65cm*width 46cm*height 84cm



Precision in Thermal Testing

The DH-300A-3 apparatus ensures precise determination of heat deformation temperature and Vicat softening point, crucial for assessing materials' performance under elevated temperatures. Its robust construction guarantees dependable results across various applications, particularly in hospital and laboratory environments.


User-Friendly Operation

With a manual power supply and simple adjustment features, the DH-300A-3 is accessible to both expert technicians and less experienced users. Its ergonomic design and clear interface streamline temperature and hardness tests, supporting consistent and accurate laboratory workflows.

FAQ's of DH-300A-3 Heat Deformation Temperature Vicat Softening Point Apparatus:


Q: How is the DH-300A-3 apparatus used in hospital settings?

A: The DH-300A-3 is used in hospital laboratories to test the thermal properties of medical plastics or polymers. Lab technicians conduct standard procedures to determine heat deformation and the Vicat softening point of various materials, aiding in quality control and safety assessments.

Q: What materials can be tested with the DH-300A-3 apparatus?

A: This device is suitable for evaluating a range of thermoplastic and polymer samples. It measures their resistance to heat and identifies the point at which they soften, making it valuable for industries and laboratories working with plastic components.

Q: When should the hardness feature be utilized during testing?

A: The hardness feature should be used during material evaluation to complement heat deformation and Vicat softening point data. It allows you to gather comprehensive insights on the material's resistance and durability under temperature stress.

Q: Where is the DH-300A-3 apparatus available for purchase?

A: This apparatus is distributed by manufacturers, exporters, suppliers, and traders located in China. It is accessible for international export or local procurement depending on your requirements.

Q: What is the benefit of a manual power supply in this apparatus?

A: A manual power supply provides greater control and flexibility during operation. Users can adjust settings easily, which enhances precision in experimental conditions and ensures reliability even when automated systems are not available.

Q: How does the voltage range benefit the user?

A: The broad voltage specification (110-215 Volt) allows the apparatus to be used in various global locations without the need for specialised electrical modifications, ensuring convenience and adaptability.

Q: What is the process for conducting a test using this apparatus?

A: To perform a test, place the material sample into the apparatus, adjust the settings manually, and follow standard protocols to measure heat deformation temperature and Vicat softening point. The process provides clear data on material performance under increasing temperatures.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Plastic and Rubber Testing Equipment' category



Back to top