Welcome to Our Company
Call Us
Call Us
+8613267004347
Ultraviolet Sterilization Furnace UV Disinfection Sterilizer DH-UV-2

Ultraviolet Sterilization Furnace UV Disinfection Sterilizer DH-UV-2

1650.00 - 2950.00 USD ($)/Set

Product Details:

  • Interface Type Physical Switch
  • Operating Voltage 220 V
  • Equipment Type Ultraviolet Sterilization Furnace
  • Max Height 320 mm
  • Port Size Standard
  • Application Medical Instrument, Laboratory, Dental, Beauty Tools Disinfection
  • Power Supply AC 220V / 50Hz
  • Click to view more
X

Ultraviolet Sterilization Furnace UV Disinfection Sterilizer DH-UV-2 Price And Quantity

  • 1 Set
  • 1650.00 - 2950.00 USD ($)/Set
  • Door Interlock prevents UV exposure
  • Mechanical Timer Switch
  • 253.7 nm
  • DH-UV-2
  • Front Opening with Viewing Window
  • 350 x 200 x 250 mm (L x W x H)
  • Stainless Steel
  • 15W x 2 (30W Total)
  • 0-60 min adjustable timer

Ultraviolet Sterilization Furnace UV Disinfection Sterilizer DH-UV-2 Product Specifications

  • Medical Instrument, Laboratory, Dental, Beauty Tools Disinfection
  • Standard
  • 2 Trays
  • Physical Switch
  • 320 mm
  • Ultraviolet Sterilization Furnace
  • Manual
  • 220 V
  • 10 kg
  • Table Top
  • Analog Timer
  • Semi-automatic
  • AC 220V / 50Hz
  • Stainless Steel Body, Protective Door Switch, Timer Function
  • Disinfection and Sterilization
  • 50 Hz
  • 0C - 40C
  • Immediate
  • 5% - 95% RH
  • Door Interlock prevents UV exposure
  • Mechanical Timer Switch
  • 253.7 nm
  • DH-UV-2
  • Front Opening with Viewing Window
  • 350 x 200 x 250 mm (L x W x H)
  • Stainless Steel
  • 15W x 2 (30W Total)
  • 0-60 min adjustable timer

Ultraviolet Sterilization Furnace UV Disinfection Sterilizer DH-UV-2 Trade Information

  • Shenzhen
  • 300 Set Per Month
  • 7 Days
  • All India

Product Description

Ultraviolet Sterilization Furnace UV Disinfection Sterilizer DH-UV-2


Principle

Outside line disinfection technology is the latest generation of international disinfection technology emerging in the late 1990s. It integrates optics, microbiology, electronics, fluid mechanics, and aerodynamics. It has the characteristics of high efficiency, broad spectrum, low cost, long life, large water volume, and no secondary pollution. It is internationally recognized mainstream consumer technology in the 21st century. Mainly used to sterilize cooked food and water. It is widely used in hospitals, food, Chinese herbal medicine, food and beverage processing and packaging equipment, health care products factories, medical products, food factories, cosmetics factories, dairy factories, wineries, beverage factories, bakeries and packaging products factories. The working principle of the device is that the ultraviolet sterilization band is mainly between 200-300nm, and the sterilization ability with the wavelength of 253.7nm is the strongest. When various bacterial viruses in water or air pass through the ultraviolet (253.7nm wavelength) irradiation area, ultraviolet rays penetrate the cell membrane and nucleus of microorganisms, destroying molecular bonds of nucleic acid (DNA or RNA), causing them to lose their replication ability or activity and die. To kill all bacterial viruses without using any chemicals. The germicidal lamp does not need to be converted into visible light. The wavelength of 100-200nm can play a good bactericidal effect. This is because the cell has a regular absorption spectrum of light waves. Ultraviolet rays at 100-200nm have maximum absorption,the absorbed ultraviolet light actually acts on the genetic material of the cell, that is, DNA, and it plays a photochemical role. The energy of the ultraviolet photons is absorbed by the base pairs in the DNA, causing the genetic material to mutate, causing the bacteria to die immediately or fail to reproduce to achieve the purpose of sterilization.


Ultraviolet disinfection technology has unparalleled sterilization efficiency. Sterilization efficiency can reach 99% -99.9%. Ultraviolet technology generally takes less than 1 second to sterilize several common bacterial viruses.However, it takes 20 minutes to 1 hour for the traditional chlorine and ozone chemical disinfection methods to achieve the UV C sterilization effect.



Using Characteristics and Scope

UV sterilizer has the characteristics of uniform water flow, no dead corners, good light irradiation conditions, thorough sterilization, low energy consumption, flexible and convenient installation, etc.The main material is stainless steel, and there is no metal ion infection problem.Product structure is sealed container quartz sleeve type.Built-in electrical control device.The key UV lamp management life is as long as 10,000 hours, reaching the international advanced level. The product has a beautiful appearance, compact structure, convenient operation and maintenance, and is widely used in industrial and mining enterprises, residential life, restaurants, hotels, institutions and schools; field forces, food processing, pharmaceutical industry, high-purity water preparation, public places or leisure tourism directly for drinking. Beverages and other industries residual chlorine is not allowed.



Advantages of UV Disinfection Technology

Ultraviolet C disinfection technology has been recognized on worldwide for the disinfection of bacterial viruses and other pathogens, It has unparalleled sterilization efficiency compared with other technologies. The germicidal effect of ultraviolet rays on bacteria and viruses is generally within one second. For traditional chlorine and ozone methods, it takes 20 to 50 minutes to achieve the germicidal effect of ultraviolet light. It has a broad spectrum of efficient sterilization, no secondary pollution, safe and reasonable design, safe and reliable operation. Simple maintenance and low cost. This equipment occupies a small area and has no noise. Continuous mass sterilization. Wide application fields and many other advantages.



Pay attention to protection

Ultraviolet rays have a powerful lethality to bacteria, and also have a certain degree of damage to the human body. The most vulnerable part of the human body is the cornea of the eyes. Therefore, you must not look directly at the lighted tube at any time to avoid injury. When it is necessary to watch, use ordinary glass (wearing glasses) or transparent plastic sheet as a protective face shield. Do not use quartz glass by mistake, because ordinary glass is almost completely impermeable to ultraviolet rays. Once injured, don't panic and burn your face. After a few days, the epidermis comes off and heals without treatment. Eye injuries can be red, swollen, tearful, and tingling, and it will take about three or four days to heal.However, in case of injury, it is still recommended to seek medical treatment immediately.



Equipment size

1. Overall length of equipment: 2000mm

2. UV working area: 1000mm

3. Feeding operation area: 500mm

4. Discharging operation area: 500mm

5. Height of entrance and exit: 200mm (adjustable)

6, entrance and exit width: 500mm



Equipment main structure

1. Work area tunnel outer body: 1.2mm stainless steel plate

2. Working chamber tunnel cavity: 1.0mm 304 high quality stainless steel plate

3. Airframe support frame: one set of square pass steel

4. Conveyor belt: high-grade Teflon mesh belt

5. Conveying roller: clean friction-resistant stainless steel roller

6. Conveying power: According to production needs, the conveying speed can be adjusted from 0-20 meters / minute.

7. Bearing beam (2 pcs), balance device: flat water cup



Equipment electrical parts

1. Mesh belt inorganic speed regulation range: 0-5m / min adjustable

2. Transportation motor: 250W

3.Governor: stepless speed regulation

4. Ammeter: a set of 20A

5. Working voltage: 220V -single-phase three-wire system / 50Hz





Precise and Reliable Disinfection

The DH-UV-2 sterilizer utilizes powerful ultraviolet-C lamps, ensuring thorough sterilization of medical instruments, laboratory samples, dental tools, and beauty equipment. Its manual mechanical timer allows users to set disinfection time up to 60 minutes, providing tailored sterilization for varying needs. The stainless steel body and analog controls make this unit durable and user-friendly for everyday professional use.


Enhanced Safety Features

Safety is central to the DH-UV-2's design. With a front opening door equipped with a viewing window and door interlock mechanism, the system prevents accidental exposure to UV radiation, ensuring user protection during operation. The furnace also operates within a wide humidity (5%-95% RH) and temperature (0C-40C) range, making it adaptable to diverse environments.


Versatile Application and Capacity

Accommodating two trays in a spacious chamber (350 x 200 x 250 mm), this sterilizer meets the demands of clinics, labs, salons, and dental offices. It is ideal for rapidly sterilizing small tools and equipment, boosting operational efficiency while maintaining high standards of hygiene and safety. Its tabletop mounting and 10 kg weight allow easy placement and mobility within any workspace.

FAQ's of Ultraviolet Sterilization Furnace UV Disinfection Sterilizer DH-UV-2:


Q: How does the DH-UV-2 sterilize items placed inside?

A: The DH-UV-2 uses ultraviolet-C (UV-C) light at a wavelength of 253.7 nanometers to destroy bacteria, viruses, and other microorganisms on the surfaces of instruments. The two 15W UV lamps deliver a total of 30W power, ensuring effective and comprehensive sterilization throughout the chamber.

Q: What safety mechanisms are built into the DH-UV-2 to protect users?

A: This model features a door interlock system that automatically turns off the UV lamps when the front-opening door is opened, preventing accidental exposure to UV radiation. The viewing window allows users to monitor the process without being exposed to the UV light.

Q: When should I use the timer, and how do I set the sterilization duration?

A: The manual mechanical timer on the DH-UV-2 allows you to select a disinfection period from 0 to 60 minutes. Choose the appropriate time based on the items' contamination level and type. Simply turn the analog switch to your desired duration before starting the process.

Q: Where can this ultraviolet sterilization furnace be installed or used?

A: With a compact, tabletop design and standard power requirements (AC 220V/50Hz), the DH-UV-2 is suitable for use in medical clinics, dental practices, laboratories, salons, and beauty parlors, as well as any facility that requires rapid, reliable sterilization of instruments.

Q: What is the recommended process for loading and operating the DH-UV-2 sterilizer?

A: To use, place cleaned and dried instruments on the two supplied trays inside the chamber, close the front door securely, and set the timer using the manual switch. The safety interlock ensures the UV lamps function only when the door is closed. After the cycle completes, open the door and remove the sterilized items carefully.

Q: What are the main benefits of using the DH-UV-2 for sterilization?

A: Primary benefits include immediate sterilization response, broad compatibility with various instruments, customizable sterilization times, robust stainless steel construction for durability, and enhanced safety through door interlock and viewing window features.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Medical Testing Machine' category



Back to top