UL94 Plastics Horizontal/Vertical Combustion Tester
1. Product model HT-408PT-PL
2. Standards
UL 94-2006 IEC60695/GB 5169/GB2408
3. Specification
3.1. Combustion rating test: (a) Vertical combustion V0V2, (b) Horizontal combustion HB, (c) 5VA/5VB rating.
3.2. Fuel gas: Methane (purity 98%), self-supplied
3.3. Fuel gas flow rate and pressure range:
(1) HB and V grade gas flow rate is 105 ml/min, back pressure is 10 mm water column or equivalent pressure
(2) 5VA and 5VB grade gas flow rate is 965 ml/min, back pressure is 125 mm water column or equivalent pressure
3.4. Flame and flame temperature:
(1) The time for a 20mm flame to rise from 100 degrees to 700 degrees is 442 seconds. The horizontal angle is 90 degrees, and the vertical angle is 20 degrees (the longitudinal axis remains on the vertical plane and forms a 20 angle with the vertical direction). The angle is adjustable up to 45 degrees. It uses natural air intake. The inner flame is 1940mm, and the outer flame is 20125mm, all adjustable.
(2) The time for a 125mm flame to rise from 100 degrees to 700 degrees is 542 seconds. The
horizontal angle is 90 degrees, and the vertical angle is 20 degrees (the longitudinal axis remains on the vertical plane and forms a 20 angle with the vertical direction). The angle is adjustable up to 45 degrees. It uses natural air intake. The inner flame is 40mm, and the outer flame is 20125mm, all adjustable.
3.5.Studio:
(1) 0.75 cubic meters, all made of high-quality cold plate electrostatic baking paint; the top of the box is equipped with a powerful exhaust system.
3.6.Test apparatus and test fixtures:
(1) Sample height adjustment method: electric
(2) Horizontal bracket adjustment method: manual.
3.7.Timing system: Human-machine interface, simple and convenient setup
(1) Number of burns: 199 times (adjustable)
(2) Burning time: 0.099.99S (adjustable)
(3) Ignition end time: 0.099.99S (adjustable)
(4) Ignition delay time: can be observed and recorded on the touch screen
(5) During the test, there is an audible alarm function.
3.8 Main components:
(1) 50WCH4 dedicated flow meter, range 16-160 ml/min, accuracy: 2%.
500WCH4 dedicated flow meter, range 0.1-1 L/min, accuracy: 2%. (2) U-shaped pressure tube 300Pa H2O back pressure liquid: water
(3) Dedicated pressure gauge: 00.2MPa
(4) Regulating valve: AR2000-08
(5) CH4 steel cylinder regulating valve, primary pressure: 0280bar, secondary pressure gauge: 07bar (self-provided)
(6) 50W temperature measuring thermocouple: 0.5mm K type (Germany) maximum resistance 1100
(7) Temperature measuring copper block: 20mm flame: weight (before drilling): 1.760.01g, diameter: 5.50mm0.01;
(8) 500W temperature measuring thermocouple: 0.5mm K type (Germany) maximum resistance 1100
(9) Temperature measuring copper block: 125mm flame: weight (before drilling): 10.00.05g, Diameter: 9.0mm0.01;
(10) Blowtorch: Homemade
Blowtorch nozzle diameter: 0.900.03mm, nozzle lamp length: 1.600.05mm, nozzle height from air inlet is 102mm;
Price: