Welcome to Our Company
Call Us
Call Us
+8613267004347
High Melt Index PP Meltblown Melt Flow Rate Tester HT-3682VM Series

High Melt Index PP Meltblown Melt Flow Rate Tester HT-3682VM Series

1699.0 USD ($)/Unit

Product Details:

  • Power Supply AC 220V, 50Hz
  • Response Time Fast, instant test result output
  • Features Automatic cut-off, built-in micro-printer, auto compensation, alarm system, easy cleaning
  • Frequency 50 Hz
  • Measuring Range 0.1 - 300 g/10 min
  • Automation Grade Semi-automatic / automatic
  • Application Melt flow rate measurement for PP, PE, and other thermoplastics, especially meltblown PP
  • Click to view more
X

High Melt Index PP Meltblown Melt Flow Rate Tester HT-3682VM Series Price And Quantity

  • 1699.0 USD ($)/Unit
  • 1 Unit

High Melt Index PP Meltblown Melt Flow Rate Tester HT-3682VM Series Product Specifications

  • AC 220V, 50Hz
  • Fast, instant test result output
  • Automatic cut-off, built-in micro-printer, auto compensation, alarm system, easy cleaning
  • Standard flow rate (as per MFR/MVR measurement requirements)
  • 50 Hz
  • Semi-automatic / automatic
  • 0.1 - 300 g/10 min
  • Melt flow rate measurement for PP, PE, and other thermoplastics, especially meltblown PP
  • 0.1 ~ 300 g/10 min (depends on material)
  • RS232, USB (online print option)
  • About 45 kg
  • 0.6 - 0.8 MPa (for pneumatic models)
  • Melt indexer with max load 21.6 kg
  • Desktop
  • Standard die orifice 2.095 mm (customizable)
  • Temperature 0.2C, Flow rate 0.1 g/10 min
  • Microcomputer/Touch screen control
  • 85% RH, non-condensing
  • 0.01 g/10 min
  • 2.095 mm die bore, 8 mm length (standard for MFR test)
  • Adjustable, up to 30 mm
  • Approx. 520 mm
  • Room temperature to 400C
  • High Melt Index PP Meltblown Melt Flow Rate Tester
  • LCD Touch Screen
  • 1 at a time
  • 220V AC
  • Quality control, research, educational labs
  • Over-temperature alarm & fault alert
  • Carburized tool steel, corrosion resistant
  • Temperature 10C - 40C, Humidity <85% RH
  • Integrated micro-printer and data storage
  • Automatic and manual selectable
  • 8 minutes
  • Standard volume for MFI/MFR standard tests
  • 0.325 kg - 21.6 kg (standard weights provided)
  • PID digital temperature control
  • 370 x 325 x 520 mm (L x W x H)
  • Air cooled

Product Description

Features:

A. Specially developed and produced for PP meltblown materials

B. Special models, easy to use, anyone can operate

C. High accuracy of temperature control, fast heating rate, 4 hours temperature drift does not exceed 0.2

D. High displacement accuracy, up to 0.01mm; the die material is tungsten carbide

E. Volumetric test without cutting, can directly output the test results

F. Accurate volume time 0.001s

G. Built-in micro printer, can print test data at any time

H. The density value of the material at a specific temperature can be calculated by the ratio of the volumetric mass method

J. It can be connected to the computer via USB, and the test conditions can be set on the computer through the software, the data can be printed, and the data can be stored (optional)

Model difference

1. HT-3682VM-BA: 4.3 inch color screen button

2. HT-3682VM-5PT: 5 inch touch screen with top and bottom structure or 5 inch touch screen with left and right structure

3. HT-3682VM-7PT: left and right structure, dual temperature monitoring 7 inch touch screen

Main technical parameters

l Temperature range: 0 -400

l Double heating ring, double P100 temperature monitoring system (for HT-3682VM-7PT)

l Temperature display resolution: 0.1

l Temperature accuracy: 0.2 (HT-3682VM-7PT: 0.2 )

l Temperature uniformity:

0.5 (HT-3682VM-7PT: 0.2 )

l Volume timing resolution: 0.001S,Accuracy:0.01S

l Chinese GB / 3682-2018S standard die / half die diameter: 2.095 0.005mm / 1.050mm 0.005mm; die length: 8.000 0.025mm / 4mm 0.025mm(half die is optional)

l American ASTM D1238 standard die / half die diameter: 2.0955 0.0051mm / 1.048mm 0.005mm; die length: 8.000 0.025mm / 4mm 0.025mm

l Loading barrel diameter: 9.550 0.007mm; length: 152 0.100mm

l Piston rod head diameter: 9.475 0.007mm, length: 6.350 0.100mm

l Weight accuracy: 0.5%

l Japan Omron photoelectric rotary displacement measurement sensor

l Mold material: tungsten carbide

l Displacement measurement

accuracy: 0.01mm

l Test load: 2160g

l Countdown: 300s

l Melting index temperature: 230

l Volume method test range:

0.1-3000cm3/10min(displacement measurement)

l Measuring range of melt-blown material mass method: (0.1 2300) g/10min(displacement measurement)

l Measurement range of non-melt spray material mass method: (0.1 100)g/10min (cutting measurement)

l Output mode: Mini automatic printout

l Power supply voltage: AC220V 10% 50HZ or AC110 / 600HZ; choose different power supply voltage according to the country of use

l Weight: 60kg


Testing procedure

(1) Turn on the power of the HT-3682VM meltblown melt index tester, adjust the level, set the temperature to 230 C, close the die plate, then put the die into the charging cylinder, click the temperature control button to let the instrument start heating at 230

(2) After constant temperature to 230 , prepare 13 15ml polypropylene PP raw material, pour the raw material into the charging cylinder and compact it with the rod, then insert the 325g load piston rod into the charging cylinder, at this time the displacement rod is placed under the weight tray, but can not touch the piston disc, then press the 1835g load sleeve on the piston rod, click the timer, the instrument starts to count down 300 seconds.

(3) When the countdown of the instrument is over 300 seconds, there will be an alarm sound, and then click Run, and then push the die baffle away, the raw material will be extruded under the load pressure of 2160g, when the piston rod touches the encoder, the instrument will start the timing. When all the raw materials are extruded, the timing will automatically end. The MFR value of the

melt-blown polypropylene PP raw material will be displayed on the screen.unit is g / 10min.

(5) Select the print result on the screen and automatically print out the test result. A

Note: According to the GB / T3682-2018 standard specification, the MFR value in the above test is the MVR value and the density obtained through the temperature of 230 .



Precision Engineering for Reliable Testing

Equipped with a carburized tool steel die and a robust PID digital thermostat, the HT-3682VM Series ensures outstanding corrosion resistance and reliable accuracy. Its temperature control (up to 0.2C precision) and rapid heating time (8 minutes) make it ideal for meltblown PP quality tests, delivering results you can trust every time.


Advanced Features Enhance Usability

With both automatic and manual cut-off, an integrated micro-printer, and touch screen control, this tester maximizes convenience and operational efficiency. Standard weights facilitate easy sample loading, while built-in alarms protect against overheating or faults, ensuring smooth operation in fast-paced laboratory environments.


Versatility in Application & Data Handling

Suitable for routine quality control, academic research, or manufacturing verification, this series supports flexible sample sizes and melt flow rates between 0.1 and 300 g/10 min. Data output options include RS232 and USB for streamlined analysis and record-keeping, assisted by a fast-response LCD touch screen for instant results.

FAQ's of High Melt Index PP Meltblown Melt Flow Rate Tester HT-3682VM Series:


Q: How does the HT-3682VM Series Melt Flow Rate Tester operate?

A: The HT-3682VM uses PID digital temperature control to precisely heat samples, and supports both automatic and manual cut-off modes. It measures the melt flow rate by extruding the polymer through a carburized steel die, with results displayed on the touch screen and stored or printed via the integrated micro-printer.

Q: What materials can be tested with this melt flow rate tester?

A: This instrument is designed for measuring the melt flow rate of a wide variety of thermoplastics, including polypropylene (PP), polyethylene (PE), and is especially effective for meltblown PP used in filtration and medical applications.

Q: When should I use the automatic versus manual cut-off feature?

A: Automatic cut-off is ideal for standard measurements, ensuring consistent timing and reduced operator error. Manual cut-off can be selected for special materials or research scenarios requiring more flexible test control.

Q: Where is this melt flow rate tester best utilized?

A: It is well-suited for quality control labs, research facilities, academic institutions, and manufacturing environments where reliable, repeatable melt flow rate results for thermoplastics are critical.

Q: What is the step-by-step process for running a test on the HT-3682VM?

A: Load the sample using a standard weight, set the desired test parameters on the LCD touch screen, allow the device to reach the setpoint temperature (about 8 minutes), and start the test. The machine will measure the melt flow rate, display results instantly, and output data to the micro-printer or via USB/RS232.

Q: How does the built-in alarm system benefit the user?

A: The over-temperature alarm and fault alert system help prevent damage to the instrument or test samples, improving lab safety and ensuring accurate, uninterrupted operation during testing.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail