Product Description
Differential scanning calorimeter DH-DSC-530LN
Introduction:
Differential scanning calorimeter is a touch screen type, which can perform glass transition temperature test, phase transition test, melting and enthalpy value test, product stability, and oxidation induction period test.
Standards:
GB/T 19466.2-2004/ISO 11357-2:1999 Part 2: Determination of glass transition temperature
GB/T 19466.3-2004/ISO 11357-3:1999 Part 3: Determination of melting and crystallization temperature and enthalpy
GB/T 19466.6-2009/ISO 11357-3:1999 Part 6: Determination of Oxidation Induction Time and Oxidation Induction Temperature
Technical parameters:
1. Temperature range: -150500(Determine the minimum temperature based on the refrigeration equipment)
2. Temperature resolution: 0.01
3. Temperature fluctuation: 0.1
4. Temperature repeatability: 0.1
5. Heating rate: 0.1100/min
6. Constant temperature time: recommended <24h
7. Temperature control method: heating, constant temperature (automatic program control)
8. DSC range: 0600mW
9. DSC resolution: 0.01mW
10.DSC sensitivity: 0.01mW
11. Working power supply: AC220V/50Hz or customized
12. Atmosphere control gas: nitrogen, oxygen (automatic switching of the instrument)
13. Gas flow: 0-300mL/min
14. Gas pressure: 0.2MPa
15. Display mode: 8-inch LCD touch screen display
16. Data interface: standard USB interface
17. Parameter standard: Equipped with standard substances (indium, tin, zinc), users can calibrate the temperature by themselves
Features:
1. The industrial-grade 8-inch touch screen is completely free from the constraints of the computer.
2. Brand new furnace structure, can be equipped with a variety of refrigeration devices.
3. USB communication interface, strong versatility, reliable and uninterrupted communication, and supports self-restoring connection function.
4. Automatically switch the two-way atmosphere flow, with fast switching speed and short stabilization time. At the same time, a protective gas input is added.
5. The software is simple and easy to operate.
Unmatched Thermal Analysis VersatilityThe DH-DSC-530LN caters to diverse research needs, including melting point, crystallization, glass transition, and purity analysis. Its wide test range of -180C to 530C (with liquid nitrogen cooling) and high data accuracy make it indispensable for comprehensive thermal characterization in laboratories.
Exceptional Precision and SafetyWith baseline repeatability at 0.02 mW and differential accuracy at 0.01 mW, this DSC ensures reliable, reproducible results. Safety is prioritized with overheat protection and automatic gas cutoff, assuring secure operation during thermal analysis processes.
User-Friendly Operation and AnalysisA 7-inch LCD touchscreen and professional multi-language software provide intuitive, fully automated control and analysis. Data management is streamlined via outputs to Excel, PDF, and graphic formats, facilitating further evaluation and reporting for research and industrial applications.
FAQ's of Differential scanning calorimeter DH-DSC-530LN:
Q: How does the DH-DSC-530LN conduct temperature calibration?
A: The instrument features automatic, multi-point temperature calibration, ensuring highly accurate and consistent temperature measurements throughout each analysis. This streamlines setup and supports reliable experimental results.
Q: What cooling options are available for the DH-DSC-530LN?
A: The DSC supports both liquid nitrogen and mechanical refrigeration systems for flexible cooling, enabling reliable operation across a temperature range from -180C to 530C.
Q: When is it beneficial to use the DH-DSC-530LN for analysis?
A: The DH-DSC-530LN is ideal when precise thermal events, such as melting point, crystallization, glass transition, or purity determination, need to be measured in laboratory environments, research and development, or quality control.
Q: Where can the DH-DSC-530LN be installed for optimal use?
A: This benchtop device is best suited for installation in temperature-controlled laboratories with 15C to 35C ambient conditions and up to 85% relative humidity (non-condensing). Its compact design fits standard laboratory workspaces.
Q: How user-friendly is the operation and data handling process?
A: Operation is fully automatic and managed through a 7-inch LCD touch screen. Advanced software supports multi-language settings and facilitates easy export of results in Excel, PDF, or graphic formats for further analysis.
Q: What safety features does the DH-DSC-530LN offer during operation?
A: It includes essential safety mechanisms such as overheat protection and automatic gas cutoff, minimizing risk to users and samples during thermal analysis procedures.
Q: What are the main benefits of using the DH-DSC-530LN in thermal analysis?
A: This DSC provides unmatched precision, automated operation, high-quality data output, low maintenance, and robust safety features, making it an excellent choice for accurate and efficient thermal analysis of single samples.