Welcome to Our Company
Call Us
Call Us
+8613267004347
DH-300B-6 Thermal Deformation, Vicat Softening Point Temperature Tester

DH-300B-6 Thermal Deformation, Vicat Softening Point Temperature Tester

3614.00 USD ($)/Set

Product Details:

  • Interface Type RS232/USB (optional)
  • Features Automatic timing, automatic temperature rise, curve display, over-temperature protection
  • Port Size Standard Specimen Basket Holders
  • Specimen Size Vicat: 1010(3~6) mm, Deflection: 12712.7(3~13) mm
  • Test Range Vicat (50C ~ 300C), Deflection (50C ~ 300C)
  • Max Height 600 mm
  • Humidity 80% RH (ambient)
  • Click to view more
X

DH-300B-6 Thermal Deformation, Vicat Softening Point Temperature Tester Price And Quantity

  • 3614.00 USD ($)/Set
  • 1 Set

DH-300B-6 Thermal Deformation, Vicat Softening Point Temperature Tester Product Specifications

  • AC 220V, 50Hz
  • No compressed gas required
  • For plastic/rubber lab analysis
  • Vicat (50C ~ 300C), Deflection (50C ~ 300C)
  • Automatic timing, automatic temperature rise, curve display, over-temperature protection
  • RS232/USB (optional)
  • Standard Specimen Basket Holders
  • Vicat: 1010(3~6) mm, Deflection: 12712.7(3~13) mm
  • 80% RH (ambient)
  • Microprocessor/PID Automatic Control
  • 600 mm
  • Determination of thermal deformation temperature and Vicat softening point of non-metallic materials (plastics, rubber, etc.)
  • Thermal Deformation and Vicat Softening Point Tester
  • Floor-standing
  • 0~10 mm
  • Temperature: 0.01C, Displacement: 0.001 mm
  • N/A (Not applicable to this tester)
  • 220V 10%, 50Hz
  • 50 Hz
  • Instantaneous electronic response
  • Automatic
  • Temperature: 0.1C, Displacement: 0.01 mm
  • Room temp. ~ 300C (adjustable)
  • Digital LCD Display
  • 80 kg
  • 6 specimens at a time
  • 50 mm/h, 120 mm/h (selectable)
  • 10 mm, 15 mm, 12.7 mm (standard specimen width)
  • 0~1 mm for deformation measurement
  • 6 stations
  • External circulation water cooling
  • 0.5C
  • Silicone oil or transformer oil
  • HB, HDT, Vicat (according to GB, ISO, ASTM standards)
  • PID microprocessor control system
  • Over-temperature, over-current, water shortage protection
  • Interchangeable weights and holders for Vicat/Deformation
  • 2.5 kW
  • 780 580 1330 mm (main unit)

DH-300B-6 Thermal Deformation, Vicat Softening Point Temperature Tester Trade Information

  • 300 Set Per Month
  • 3 Days

Product Description

DH-300B-6

Thermal Deformation, Vicat Softening Point Temperature Tester


Application:

This machine is a non-metallic material testing instrument designed and manufactured according to the latest international standards and national standards. It is mainly used for non-metal such as plastic, hard rubber, nylon, electrical insulating materials, long fiber reinforced composite materials, high strength thermosetting laminates. Determination of the heat distortion temperature of the material and the Vicat softening point temperature. It is easy to operate and precise in control. It is a highly intelligent test instrument widely used in colleges and universities, research institutes and product quality supervision and inspection units. It adopts single-chip control, PID phase-modulated output, with upper limit temperature setting, and automatically stops heating when the test temperature reaches the upper limit temperature.

Standards:

GB/T1633 "Determination of vicat softening temperature (VST) of thermoplastics"

GB/T1634 "Determination of plastic load deflection temperature part 1: general test method"

GB/T8802 "Determination of softening temperature of plastic pipe fittings"

Equals to ISO2507-1:2017

IS075-2013 "Determination of plastic load deformation temperature"

ASTM D 648 "Plastic heat deflection temperature test method"

ASTM D 1525 "Plastic vicat softening temperature test method"

Advantages:

1.Intelligent PID adjustment, accurate heating rate, precise temperature control

2.Can do thermal deformation test of various standard specimen

3.Can do Vicat softening point test of various standard specimen

4.The required load can be automatically calculated according to the test standard and sample size

5.Two heating rates can be selected, free switching, simple operation

6.When the test is completed or the temperature exceeds the upper limit, the temperature control will be turned off and shut down automatically

7.With software over-temperature protection and leakage protection

8.Has air-cooled and water-cooled dual rapid cooling

Specification:

1). Temperature control range: ambient temperature300

2). Heating rate: (12010)/h (121)/6min

(505)/h (50.5)/6min

3). Temperature indication error: 0.1

4). Temperature control accuracy: 0.5

5). Maximum deformation indication error: 0.001mm

6). Deformation measurement range: 0-10mm

7). Number of sample racks: 6

8). The weight of the load bar and the tray: 68g

9). Test span range: 64 or 100mm according to the standard

10). Fuel tank volume: about 25L

11). Heating medium: methyl silicone oil

12). Cooling method: external water cooling

13). Heating power: 3.0kw

Configuration

1) 1x host

2) 6 x sample holders

3). 6 x heat deformation indenters

4). 6 x Vicat needles

5). 6 x sets of weights (including boxed weights) (attached table)

6). 1x power socket



Precision Thermal Analysis for Non-Metallic Materials

The DH-300B-6 tester offers reliable determination of thermal deformation temperature and Vicat softening point in plastics, rubber and other non-metallic materials. With microprocessor-based PID automatic control and high-accuracy sensors, laboratories benefit from precise thermal analysis, essential for material development and quality control.


Automatic Operations and Flexible Testing

Automation features such as automatic temperature rise, timing, and curve display enhance laboratory workflow and reduce manual intervention. The tester's interchangeable weights and holders allow for seamless switching between Vicat and deformation tests, making it suitable for a variety of standard specimen sizes.


Comprehensive Safety with User-Centric Design

The DH-300B-6 is built with multiple safety protections, including over-temperature, over-current, and water shortage alarms. Its user-centric digital LCD interface combined with RS232/USB optional output, ensures both safety and convenience, ideal for floor-standing lab setups.

FAQ's of DH-300B-6 Thermal Deformation, Vicat Softening Point Temperature Tester:


Q: How does the DH-300B-6 ensure precise temperature control during testing?

A: The DH-300B-6 utilizes a PID microprocessor control system, which maintains temperature within a high-precision tolerance of 0.5C and displays readings to 0.01C. This ensures consistent heating for accurate Vicat and deformation measurements.

Q: What processes can be performed with this tester, and which standards are supported?

A: This tester is designed for Vicat softening point and thermal deformation (HDT) testing according to GB, ISO, and ASTM standards. It supports various test speeds and specimen sizes, making it versatile for laboratory material analysis.

Q: When should I use external circulation water cooling, and what benefits does it provide?

A: External circulation water cooling is used to maintain consistent thermal conditions during and after high-temperature testing cycles. It helps achieve rapid sample cooling and protects the instrument, especially during continuous or high-throughput testing.

Q: Where is the DH-300B-6 commonly applied, and what materials can be tested?

A: The DH-300B-6 is commonly found in research, quality control, and industrial laboratories analyzing plastics, rubber, and other non-metallic specimens, supporting standard sizes for Vicat and HDT/deflection tests.

Q: What is the process for switching between Vicat and deformation tests in this equipment?

A: The machine features interchangeable sample holders and weights. Operators can easily select and install the appropriate holder and set the control interface for either Vicat or deformation testing, all managed conveniently via the automated digital controller.

Q: How many specimens can be tested at once, and what is the advantage?

A: Up to six specimens can be analyzed simultaneously. This high-throughput capability increases laboratory efficiency and data throughput, saving both time and resources.

Q: What safety features are included, and how do they benefit the user?

A: The DH-300B-6 includes safety measures such as over-temperature, over-current, and water shortage protection. These features safeguard both the equipment and the user, reducing the risk of accidents and instrument damage.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

Other Products in 'Plastic and Rubber Testing Equipment' category



Back to top