  • Resolution 0.1%
  • Specimen Size Length 70~150 mm, Width 6.5~10 mm, Thickness 4.5 mm Millimeter (mm)
  • Temperature Room Temperature (10C~35C) Celsius (oC)
  • Accuracy 0.2% (Oxygen Concentration) %
  • Automation Grade Fully Automatic
  • Display Type Touch Screen Display
  • Gas Pressure 0.2~0.3 MPa mpa
  • Click to view more
X

Automatic Oxygen Index Tester for Flammability Testing DH-OI-01 Price And Quantity

  • 2357.00 INR/Unit
  • 1 Unit

Automatic Oxygen Index Tester for Flammability Testing DH-OI-01 Product Specifications

  • Flammability Testing of Plastics & Polymers
  • 50 Hz Hertz (HZ)
  • 1 at a time
  • Automatic (Touch Screen Control)
  • Approx. 25 kg Kilograms (kg)
  • Lab Testing of Material Flammability
  • O2 Index 0~100% Kelvin (K)
  • Touch Screen Interface
  • Adjustable, 10~100 mm/min
  • 220V Volt (V)
  • AC 220V 10%, 50Hz
  • Automatic Gas Control, Digital Display, Pressure Regulators
  • 6 mm Gas Inlet
  • Bench-top
  • Automatic Oxygen Index Tester
  • Oxygen Index 0~100%
  • 400 mm (Combustion Cylinder)
  • 75% RH
  • 3 seconds Seconds
  • Touch Screen Display
  • Fully Automatic
  • 0.2~0.3 MPa mpa
  • 0.2% (Oxygen Concentration) %
  • Length 70~150 mm, Width 6.5~10 mm, Thickness 4.5 mm Millimeter (mm)
  • Room Temperature (10C~35C) Celsius (oC)
  • 0.1%
  • Electronic Ignition
  • Nitrogen & Oxygen
  • Dust-Free, Ventilated Laboratory
  • Automatic/Manual
  • Low Pressure & Over-pressure Protection
  • USB/Printer optional
  • Borosilicate Glass

Automatic Oxygen Index Tester for Flammability Testing DH-OI-01 Trade Information

  • 300 Unit Per Month
  • 3 Days

Product Description

Automatic Oxygen Index Tester DH-OI-01

Advantage:

1. Full-color touch screen control, just set the oxygen concentration value on the touch screen,

the program will automatically adjust to the oxygen concentration balance and emit a beep sound prompt, eliminating the trouble of manually adjusting the oxygen concentration;

2. The stepped proportional valve is used to greatly improve the control accuracy of the flow

rate. The closed-loop control is adopted. The oxygen concentration drift program is automatically adjusted back to the target value during the test, avoiding the disadvantage that the traditional oxygen index meter cannot adjust the oxygen concentration during the test. Improve test accuracy.

 

Application:

It is suitable for the determination of the combustion properties of materials such as plastics,

rubber, fibers, foams, films and textiles, that is, the concentration percentage of the

lowest oxygen in which the polymer just maintains combustion.

 

Features:

The combustion tube is made of high temperature resistant high quality quartz glass tube (inner diameter 85mm, length 300mm)

Outlet diameter: 40mm

The mixer is filled with glass beads to mix oxygen and nitrogen evenly. (Bead 4.5mm filling height 95mm, label one bag)

Self-supporting sample holder, which can hold the sample vertically; (optional non-self-supporting type frame)

Adopting relay control system, all electronic originals adopt domestic leading brands, which can better guarantee the performance and reliability of the machine.

The equipment has the following safety protection devices: power supply overload, short circuit protection, and control loop overload protection.

 

Standards:

In line with GB/T 2406.2-2009, GB/T 2406.1-2008 standard

Applicable standards:

ASTM D 2863, ISO 4589-2, NES 714 GB/T 5454 GB/T 10707 GB/T 8924-2005 GB/T 16581-1996

NB/SH/T 0815-2010 TB/T 2919-1998 IEC 61144-1992 ISO 15705-2002 ISO 4589-2-1996

 

Main Technical Parameter:

1. Adopt imported oxygen sensor, oxygen concentration can be digital displayed without calculation.the accuracy is higher and more accurate, the range is 0-100%

2. Digital resolution: 0.1%

3. Measurement accuracy: 0.1 level

4. The touch screen setting program automatically adjusts the oxygen concentration

5. One-click calibration accuracy

6. One-click concentration ratio

7. Automatic alarm sound when the oxygen concentration is stable

8. With timing function

9. Can store experimental data

10. Can query historical data

11. Can clear historical data

12. Can choose whether to burn 50mm

13. Air source failure prompt

14. Oxygen sensor fault prompt

15. Prompt for wrong connection of oxygen and nitrogen

16. Oxygen sensor aging tips

17. Standard oxygen concentration input

18. The diameter of the combustion tube can be set (two common specifications are available)

19. Flow adjustment range: 0-20L/min (0-1200L/h)

20. Quartz glass tube: 75cm (can be customized according to user requirements)

21. Gas velocity in the combustion tube: 40mm2mm/s

22. Overall dimensions: 650mm400830mm (can be customized according to user requirements)

23. Pressure gauge accuracy level 2.5, resolution: 0.01MPa

24. Test environment: ambient temperature: room temperature 50 ;relative humidity: 70%;

25. Input pressure: 0.05-0.3MPa

26. Working pressure: nitrogen 0.15-0.20Mpa oxygen 0.15-0.20Mpa

27. The sample holder can be used for soft and hard plastics, various building materials, textiles, fire doors, etc.

28. Propane (butane) ignition system, the ignition nozzle is made of a metal tube, and the end has a nozzle with an inner diameter of 21mm, which can be bent freely. Can be inserted into the combustion tube to ignite the sample, flame length: 164mm, size 5mm-60mm can be adjusted freely,

29. Gas: Nitrogen and oxygen for industrial use, purity>99%; (user-provided/regular gas station industrial oxygen purity is generally between 99.2%-99.3%).

30. Power requirements: AC220 (+10%) V, 50HZ

31. Maximum power consumption: 150W

32. Self-supporting material sample clamp: can be fixed on the axis of the combustion cylinder and can clamp the sample vertically

33. Non-self-supporting material sample holder: can fix the two vertical sides of the sample to the frame at the same time (optional/applied to soft and non-self-supporting materials such as textiles)

Standard configuration:

1. Main unit (size: length * width * height 360mm * 250mm * 550mm) 1 set

2. Burning tube 1 set

3. Ignition 1 pcs

4. Power cord 1 pcs

5. Spare glass tube 1 pcs

6. Glass beads 1 bag (into the combustion column)

7. Nylon tube 4 1.2 m (connecting the combustion column to the main unit)

8. Sealing ring some

9. Pointed sample holder 1 set

10. Metal mesh (into the combustion column) 1 pcs

11. Plastic air outlet plate 1 pcs

12. Rubber hose 2 pcs

13. M101 inner joint screw 1pcs (within the combustion column)

14. M101 joint nut 1 piece (connected to the main unit)

15. Instructions 1 copy

16. Non-self-supporting sample holder 1 set (optional)